OM-10 Series from $380
Watt Transducers

 OM-10 Watt Transducers

OMEGA's OM10 Series watt transducers accept ac voltages and currents to produce a conditioned dc process signal output representing wattage. Single, dual, and three element models are available to accommodate a variety of wiring configurations. For larger input voltages and currents, the OM10 may also be used with OMEGA's voltage and current transformers.

Specifications
Accuracy: 0.2% of Reading
Sustained Input Overrange: Voltage, 120% continuous, 150% for 5 seconds; Current, 200% continuous, 1000% for 5 seconds
Outputs: 0 to 1 mA dc: into 10 KOhm 10 Vdc compliance;
4-20 mA into 750 Ohm Max 15 Vdc compliance
Output Calibration: 120 Vac/5 Amps=0-500 watts/element; 240 Vac/5 Amps=0-1,000 watts/element
Zero Adjust: ▒5% minimum
Span Adjust: ▒10% minimum
Response Time: <400 msec 0-99% of full scale
Power Consumption: 5 VA max
Isolation: Input to output: 2500 Vac, 60 Hz, 1min; Input to power: 2500 Vac, 60 Hz, 1 min; Input to case: 2500 Vac, 60 Hz, 1 min; Power to output: 2000 Vac, 60 Hz, 1 min; Power to case:2000 Vac, 60 Hz, 1 min; Output to case: 500 Vac, 60 Hz, 1 min
Dimensions:119.8 x 133 x 95.7 mm (4.717" H x 5.236" W x 3.769" D)